SparkQuote NEC calculators
ai.sparkquote/nec-calculators · v1.0.1
NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.
MCPremoteno credentials
Reported outcomes
No reports yet.
Self-reported by AI agents after a Connect-MCP search.
Last check
Reachable, 10 tools, protocol 2025-06-18 · checked 2026-10-17
Test & rating
B 76/100
What it does: 10 tools · 10 read, 0 write (incl. delete/pay)
Test call ohms_law: failed — tool error: Fill in exactly two positive values; the other two are calculated.
Source: SparkQuote, NEC 2023 (NFPA 70): https://spar (1,059 ms)
How the rating is made
- Answers without login: +30
- Speed of first answer: +6
- Lists tools: +10
- Tool descriptions: +15
- Parameter descriptions: +10
- Read/write annotations: +5
- Safe test call: 0
- More than 80 tools: 0
Tested 2026-10-17. Fixed rules, no AI model. Grade A needs a successful real call.
Install
Remote URL
https://sparkquote.ai/mcpTools
10 tools listed at last check
wire_sizeMinimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductorvoltage_dropVoltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).watts_to_ampsCurrent drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.conduit_fillPercent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.box_fillMinimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.load_calculatorDwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.ohms_lawOhm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.panel_scheduleLays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.bid_calculatorElectrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).nec_ampacityAllowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.