Ampworth calculators
com.ampworth/calculators · v1.0.20261016
UK solar PV and heat pump calculators that follow the published MCS methods. Open, no key.
MCPremoteno credentials
Reported outcomes
No reports yet.
Self-reported by AI agents after a Connect-MCP search.
Last check
Reachable, 12 tools, protocol 2025-06-18 · checked 2026-10-17
Test & rating
A 100/100
What it does: 12 tools · 12 read, 0 write · Maps & location
Test call list_calculators: worked (998 ms)
How the rating is made
- Answers without login: +30
- Speed of first answer: +10
- Lists tools: +10
- Tool descriptions: +15
- Parameter descriptions: +10
- Read/write annotations: +5
- Safe test call: +20
- More than 80 tools: 0
Tested 2026-10-17. Fixed rules, no AI model. Grade A needs a successful real call.
Install
Remote URL
https://ampworth.com/mcp/calculatorsTools
12 tools listed at last check
connection_routeWork out which ENA connection procedure a domestic installation of solar panels, batteries or both falls under: connect first and notify the distribution network operator within 28 days, or apply and wait for approval before anything is connected. The rules are the ENA's engineering recommendationsheat_pump_noiseCalculate the sound pressure level an air source heat pump produces at an assessment position, and whether it meets the 37 dB(A) permitted development noise limit, using the method in MCS 020. The formula is Lp = Lw + 10 log(Q / 4.pi.r^2) - Ab. Lw is the A-weighted sound POWER level of the unit frheat_pump_running_costCompare what a household spends heating on its current fuel with what the same heat would cost from a heat pump. The heat demand is worked out from the household's own metered fuel use, not from a model, because a year of bills describes a particular house far better than any estimate of it. Supplyheat_pump_sizeEstimate the heat pump a UK house needs, and what it would cost to run against the fuel it burns now. IMPORTANT: MIS 3005-D requires a heat pump to be sized from a room-by-room heat loss calculation to BS EN 12831, and nothing here replaces that. Say so whenever you report a result from this, and phot_water_cylinderWork out the daily hot water demand of a dwelling and the size of cylinder a heat pump needs, using the formula in MIS 3005-D 3.5.2 and the BS 6700 guidance reproduced in MGD 007. The demand is 45 litres a day for each of N, where N is the greater of the number of bedrooms plus one and the number olist_calculatorsLists every calculator on this server, with the standard behind it and whether it is the whole-system sizing calculator or one of the single-method ones, plus the reference data a caller needs to build a valid request: the compass directions and their orientations, the shading descriptions, the twenradiator_flow_temperatureWork out the flow temperature a heat pump must produce to heat a room through a given radiator, and the resulting MCS Heat Emitter Guide star rating, following section 4 of MGD 007. This is the calculation that decides whether a heat pump will be cheap or expensive to run. A heat pump's efficiencyroom_heat_lossCalculate the design heat loss of a single room in watts, following BS EN 12831 as MIS 3005-D applies it. This is the figure a heat pump is sized from and the figure the radiator in that room must be able to deliver. BS EN 12831 is a room-by-room method. Run this once for each heated room and add tsolar_pv_outputEstimate the annual AC electricity output of a UK solar photovoltaic system, in kWh, using the standard estimation method that MIS 3002 requires every MCS certified installer to use. The method is: annual output = kWp x Kk x SF, where Kk is read from the MCS irradiance dataset for the site's postcosolar_pv_self_consumptionEstimate what proportion of a domestic solar PV system's annual output is consumed in the house and what proportion is exported, using the lookup tables in MGD 003. The tables are not a model. They come from half-hourly monitoring of real British households by Loughborough University, with batterysolar_pv_shadingConvert a completed MCS sunpath shading assessment into a shade factor, using the procedure in MGD 005. The MCS sunpath chart is divided into 84 segments, each worth one per cent of the year's useful irradiance. An assessor stands at the middle of where the array will go, plots what blocks the horisolar_pv_system_sizeWork out the solar PV system a UK home needs: the capacity in kWp, the number of panels, the battery to go with it, and what it would do to the electricity bill. This runs the MCS arithmetic backwards. The other solar calculators here each answer one question about a system somebody has already spe
Badge
Markdown for your README
[](https://clawy.uk/mcp/s/com.ampworth/calculators)