Connect-MCP

The New Engineer — HVAC

com.thenewengineer/hvac · v1.3.0

IFC models: duct networks, circuits, pressure drop. EN 12828 vessels, EN 378, Swiss refrigerants.

MCPremoteno credentials

Reported outcomes

No reports yet.

Self-reported by AI agents after a Connect-MCP search.

Last check

Reachable, 11 tools, protocol 2025-06-18 · checked 2026-10-17

Test & rating

B 88/100

What it does: 11 tools · 7 read, 4 write

No tool could be tested safely. Only read-only tools that need no input are called.

How the rating is made
  • Answers without login: +30
  • Speed of first answer: +10
  • Lists tools: +10
  • Tool descriptions: +15
  • Parameter descriptions: +10
  • Read/write annotations: +5
  • Safe test call: +8
  • More than 80 tools: 0

Tested 2026-10-17. Fixed rules, no AI model. Grade A needs a successful real call.

Install

Remote URL
https://thenewengineer.com/mcp

Tools

11 tools listed at last check
  • size_expansion_vessel DETERMINISTIC: the same inputs always give the same result — from any AI, on any day. Figures come from the standard's tables and formulas, never from a language model's estimate. Every step is auditable. Size the expansion vessel and pressurisation of a closed heating or chilled-water circuit
  • water_content_from_vessel DETERMINISTIC: the same inputs always give the same result — from any AI, on any day. Figures come from the standard's tables and formulas, never from a language model's estimate. Every step is auditable. Deduce the water content of an installation from the expansion vessel already fitted. WHAT TH
  • check_refrigerant_switzerland DETERMINISTIC: the same inputs always give the same result — from any AI, on any day. Figures come from the regulation's annexes and thresholds, never from a language model's estimate. Every step is auditable. Swiss refrigerant regulation check (ORRChim / ChemRRV annex 2.10, OFEV synthesis of May 2
  • check_en378_zones DETERMINISTIC: the same inputs always give the same result — from any AI, on any day. Figures come from the standard's tables and formulas, never from a language model's estimate. Every step is auditable. EN 378 applied to BUILDING projects, volume by volume. An installation does not occupy one ro
  • read_ifc_overview CALL THIS FIRST, as soon as the user gives you a token. It answers within seconds, while the network graph is still being built - use that time to think. THE CIRCUITS OF A MODEL IN FOUR CALLS: 1. read_ifc_overview - this call: the types of the model. 2. apply_ifc_rules - your rules. Give air ha
  • apply_ifc_rules Turn what you read in the overview into rules the tool replays on EVERY piece of the model, including the ones you were never shown. THIS IS HOW THE TOOL LEARNS A MODEL. read_ifc_overview gives you some fifty groups — one per object type, not one per piece. You answer with RULES on those groups, an
  • read_ifc_networks DETERMINISTIC: networks come from geometry, not from a guess. The same model always gives the same networks, from any AI, on any day. Read the networks of an IFC model already uploaded by the user. WHAT A NETWORK IS. A set of parts that touch each other, cut at equipment: a pump, an air handling u
  • name_ifc_networks Apply the names you propose, and get back the updated report. THE NAMES ARE YOURS, THE NETWORKS ARE NOT. You are naming what the tool measured; you are not changing what it measured. Nothing you send here alters a network, a part, or a correction. WHAT COMES BACK. The updated report, a 3D link whe
  • trace_duct_circuits THE CIRCUITS THE FANS OF A MODEL ARE SIZED ON, found without anyone clicking and computed on the pressure-drop page, where the user confirms types and flows and reads the pressure drops. ONLY UNITS AND FANS ARE EXCHANGED. The tool never sends you system names: it sends the air handling units and fa
  • open_ifc_upload Show an upload box in the conversation where the user can drop an IFC file (.ifc) of a building services model (HVAC, plumbing, heating). The file goes straight from the user's browser to thenewengineer.com - you never see it. CALL THIS when the user wants to analyse an IFC model and has not yet gi
  • ifc_upload_result Where the upload stands. When `state` is `depose`, `token` is the token to pass to read_ifc_networks.

Badge

Connect-MCP badge for com.thenewengineer/hvac

Markdown for your README
[![Connect-MCP](https://clawy.uk/mcp/badge/com.thenewengineer/hvac.svg)](https://clawy.uk/mcp/s/com.thenewengineer/hvac)